Commissioning
PART III: Field Execution, Fault Detection, and Asset Management
Session 10: Field Calibration Using Mobile Devices and Sensors
Course Code: CX-06
Goal: Perform accurate sensor calibration and data recording during field commissioning by connecting mobile devices to BAPI Bluetest sensors and using CUBE Box for calibration validation.
Session Overview
Duration: 1 Hour
Format: Instructor-led (via Microsoft Teams or in-person)
Level: Advanced (Ideal for field technicians, commissioning engineers, and sensor specialists)
Resources Provided:
- BAPI Bluetest Sensor Setup Guide
- Mobile Calibration App Quick Reference
- Calibration Data Recording Template
- Calibration Validation Best Practices Sheet
Learning Objectives
By the end of this session, participants will be able to:
- Connect mobile devices to BAPI Bluetest sensors for calibration.
- Perform live calibration recording with mobile devices, ensuring data accuracy and error reduction.
- Use CUBE Box for enhanced calibration validation.
- Save calibration records directly into commissioning reports for future reference.
Session Agenda
CX6.1 Connecting Mobile Devices to BAPI Bluetest Sensors
- Overview of BAPI Bluetest Sensors:
- Introduction to BAPI Bluetest sensors and their role in field calibration.
- How to connect mobile devices to BAPI Bluetest sensors for real-time calibration data collection.
- Device Setup:
- Step-by-step instructions for setting up mobile devices to work with Bluetest sensors.
- Ensuring proper connectivity between devices and sensors for smooth calibration operations.
CX6.2 Live Calibration Recording and Error Reduction Strategies
- Calibration Process:
- How to use the mobile app to perform live calibration on-site with BAPI Bluetest sensors.
- Recording calibration data and ensuring accurate readings.
- Error Reduction Strategies:
- Common calibration errors and how to reduce them during field operations.
- Best practices for troubleshooting and ensuring high-quality calibration results.
CX6.3 Using CUBE Box for Enhanced Calibration Validation
- Calibration Validation in CUBE Box:
- How to validate calibration data using CUBE Box for improved system accuracy.
- Reviewing calibration performance reports and making necessary adjustments.
- Ensuring Compliance:
- Ensuring that calibration results meet industry standards and specifications using CUBE Box validation tools.
CX6.4 Saving Calibration Records Directly into Commissioning Reports
- Recording Calibration Results:
- How to save calibration data directly into CUBE Cx commissioning reports.
- Ensuring that calibration records are properly documented and stored for future audits or inspections.
Hands-On Preview (Optional if time allows)
- Connect a mobile device to a BAPI Bluetest sensor and perform live calibration.
- Record calibration data and validate it using CUBE Box.
- Save calibration results into a sample commissioning report.
Post-Session Action Items
- Review calibration workflows and ensure mobile devices are properly set up for field calibration tasks.
- Test the BAPI Bluetest sensor integration with your mobile devices in the field.
- Update your calibration reporting procedures to include direct recording into commissioning reports.
- Implement error reduction strategies to ensure accurate calibration results during field commissioning.
Note: When scheduling, make sure to include this session code: CX-06.
Schedule Your One-to-One Session